| Device Type | Modbus TCP (Ethernet) | RS485 | Curtailment | Reactive power control |
|---|---|---|---|---|
| Single Phase (1-3kW) | ❌ | ✅ | ❌ | — |
| Single Phase (3-6kW) | ||||
| Single Phase (7-10kW) | ||||
| Three Phase (3-25kW) | ||||
| Three Phase (30kW) | ||||
| Three Phase (36-60kW) | ||||
| Three Phase (70-110kW) |
| Device Type | Modbus TCP (Ethernet) | RS485 | Curtailment | Reactive power control |
|---|---|---|---|---|
| AF1-3.6K-SL-1 | ❌ | ✅ | ❌ | — |
| AF3-3.6K-SL | ||||
| AF4-6K-SLP | ||||
| AF1-6K-SL-0 | ||||
| AF3-9.6K-DH | ||||
| AF3-15K-MTH | ||||
| AF3-30K-TH | ||||
| AF36-50K-TH | ||||
| AF3-12K-THP | ||||
| AF3-30K-TH-0 | ||||
| AF3-12K-THP-0 |
Power On the Inverter
Navigate to the Main Menu
Enter the Settings Menu
Find Communication Options
Set Communication Protocol
Adjust Communication Parameters
| Parameter | Value |
|---|---|
| Baud Rate | 9600 or 19200 bps |
| Parity | None or Even |
| Data Bits | 8 |
| Stop Bits | 1 |
Assign Modbus Address